Ãëàâíàÿ

UDC 621.383.52.8

The application of photodetector preamplifier modules as control ones to reduce the measurement error

Nitsovych B. M., Doctorovych I. V., Hodovaniouk V. N., Butenko V. K., Yuryev V. H.

To reduce the manufacturer's risk in the development and production of photodetectors and photodetector preamplifier modules, a manufacturing parameters margin is being introduced. The main relative measurement error appears in the formula for the margin determination. At a high error level a part of good products is rejected as defective. The investigation results of voltage responsivity (SV) and detectivity (Dλ*) measurement procedure metrological characteristics are given in the paper, a scope for reduction of the main relative measurement error is shown.

Ukraine, Chernovtsy, “Ritm” CDD (Central Design Department).